fixed toxic and harmful gas monitoring detection system with 4-20mA or RS485 output

Place of Origin Henan, China
Brand Name chicheng
Certification CE
Model Number QB2000N
Price $200.00 - $300.00/Pieces
Packaging Details in standard export carton package
Supply Ability 5000 Piece/Pieces per Month
Product Details
Type Industry Gas Detector Customized Support OEM, ODM
Name Toxic Gas Detection System Model QB2000N
Sensor Catalytic Combustion Gas Sensor Detected Gas Toxic And Harmful Gas
Output Signal 4-20mA Or RS485 Working Temperature -20~60 Degree
Ex-proof Grade Ex DIICT6 GB IP Grade IP66
Size Of External Carton 27*23*13cm Warranty Free Calibration And Warranty Within A Year
Port Tianjin, Qingdao, Shanghai, HK Etc.
Leave a Message
Product Description
Fixed toxic gas detection system with ATEX certificate QB2000N is a fixed gas detecting transmitter, with 4-20 mA or RS485 ModBus RTU output proportional to the gas leakage concentration with original imported catalytic combustion or electrochemical sensor. It monitors gas leakage by natural diffusion.
fixed toxic and harmful gas monitoring detection system with 4-20mA or RS485 output 0
Features:
♦4-20mA analog output for direct communication to DCS system ♦Relay output for connecting external device ♦LCD display screen(LED display screen optional) ♦Advantage: Sensor module(block) design on -spot replacement s and automatically distinguish sensor fault and current display fault simultaneously. ♦Password verification for repeat operation, avoid fault operations. ♦-40~+70℃ following compensation for accurate detecting. ♦Twp grade visual alarms on-site and Relay (connected with audible/visual alarms or drive exhaust device). ♦User-selectable alarm setpoint(s).
Detailed Images
fixed toxic and harmful gas monitoring detection system with 4-20mA or RS485 output 2
fixed toxic and harmful gas monitoring detection system with 4-20mA or RS485 output 4
fixed toxic and harmful gas monitoring detection system with 4-20mA or RS485 output 6
fixed toxic and harmful gas monitoring detection system with 4-20mA or RS485 output 8
Model
QB2000N fixed toxic gas detection system
Sensor type
Honeywell/CITY gas sensor
Detected gas
0-100ppm  (other gas range, please check the table)
Resolution
1ppm
Operating Temperature
-20℃~+60℃
Output signal
4 to 20mA standard signal(RS485 output optional)
Power supply
16~30V DC
Mounting Screw thread
M20*1.5 or G1/2.
Explosion proof class
Ex d IICT6Gb
Certificate
CE/ATEX/SIL/CNEX
fixed toxic and harmful gas monitoring detection system with 4-20mA or RS485 output 10
fixed toxic and harmful gas monitoring detection system with 4-20mA or RS485 output 12
fixed toxic and harmful gas monitoring detection system with 4-20mA or RS485 output 4
fixed toxic and harmful gas monitoring detection system with 4-20mA or RS485 output 16
fixed toxic and harmful gas monitoring detection system with 4-20mA or RS485 output 18
fixed toxic and harmful gas monitoring detection system with 4-20mA or RS485 output 20
fixed toxic and harmful gas monitoring detection system with 4-20mA or RS485 output 4
fixed toxic and harmful gas monitoring detection system with 4-20mA or RS485 output 24
Recommend Products
fixed toxic and harmful gas monitoring detection system with 4-20mA or RS485 output 26
fixed toxic and harmful gas monitoring detection system with 4-20mA or RS485 output 28
fixed toxic and harmful gas monitoring detection system with 4-20mA or RS485 output 30
fixed toxic and harmful gas monitoring detection system with 4-20mA or RS485 output 32
fixed toxic and harmful gas monitoring detection system with 4-20mA or RS485 output 34
fixed toxic and harmful gas monitoring detection system with 4-20mA or RS485 output 4
fixed toxic and harmful gas monitoring detection system with 4-20mA or RS485 output 38
fixed toxic and harmful gas monitoring detection system with 4-20mA or RS485 output 40
Installation cases
fixed toxic and harmful gas monitoring detection system with 4-20mA or RS485 output 42
Parking lot case
fixed toxic and harmful gas monitoring detection system with 4-20mA or RS485 output 44
For refrigerant gas detection
fixed toxic and harmful gas monitoring detection system with 4-20mA or RS485 output 46
For chemical factory
fixed toxic and harmful gas monitoring detection system with 4-20mA or RS485 output 48
For coal mine case
fixed toxic and harmful gas monitoring detection system with 4-20mA or RS485 output 50
fixed toxic and harmful gas monitoring detection system with 4-20mA or RS485 output 4
fixed toxic and harmful gas monitoring detection system with 4-20mA or RS485 output 54
FAQ
Q1:Are you a trading company or manufacturer ? A1:We are manufacturer.
Q2:What about the payment method? A2:T/T, Paypal, Western Union, L/C is available.
Q3:Does your company accept customization? A3:We do customizing service for customers.
Q4:What about the Shipment? A4:We'll choose proper transportation mode based on the weight of goods, usually arrange shipment by air express such as DHL,FEDEX,TNT or UPS.
Q5:What about after-sale service? A5:12 months warranty for all kinds of products.

Q6.Do you have any MOQ limit? A6: We don’t have a MOQ limit, 1 pc are also welcome.