0-100%LEL CH4 detector 2 relay and 4-20mA output used in lpg gas and biogas industry for CH4 detection

Place of Origin Henan, China
Brand Name Chicheng
Certification CE
Model Number QB2000N
Price $155.00/Units 1-9 Units
Packaging Details Carton box <br>Dimension:21.5*17*10cm ,gross weight: 1.53kg <br>With alarm light: dimension 22.5*19*10cm, gross weight:2.1kg
Supply Ability 5000 Set/Sets per Month
Product Details
Type Gas Leak Detection Customized Support OEM, ODM
Product CH4 Detector Protection Grade IP66
Voltage DC24V Material Cast Aluminum
Accuracy ≤ ± 3% F.S Screen LED
Model QB2000N Color Yellow
Sensor Catalytic Combustion Sensor Weight Around 1200g
Port Qingdao/Shanghai/Tianjin
Leave a Message
Product Description

QB2000N Fixed CH4 detector with range of 0-100%LEL,2 relay and 4-20mA signal output,used in lpg gas and biogas industry for CH4 detection

Fixed LPG gas leak detector product description

 0-100%LEL CH4 detector 2 relay and 4-20mA output used in lpg gas and biogas industry for CH4 detection 0

QB2000N is Industrial grade LCD/LED gas leack detector, with 4-20 mA or RS485 ModBus RTU output proportional to the gas leakage concentration with original imported electro-chemical sensor. It has been widely used in petrol, chemistry, metallurgy, artifice, gas transportation, biological medicine and water procession etc. 

 

The online gas detector monitors gas leakage by natural diffusion.It can be directly connected with DCS systems or Central unit. With relay output, once the concentration exceed the preset alarm point(threshold), it will start the acoustic-optical alarm on the central unit and drive the external equipment like exhaust fans.

 

Fixed LPG gas leak detector product features

0-100%LEL CH4 detector 2 relay and 4-20mA output used in lpg gas and biogas industry for CH4 detection 20-100%LEL CH4 detector 2 relay and 4-20mA output used in lpg gas and biogas industry for CH4 detection 4

  • Changable Sensor mould
  •  Relay output for connecting external device
  •  LCD display screen(LED display screen optional)
  •  Password verification for repeat operation, avoid fault operations.
  •  Second grade visual alarms on-site and Relay(connected with audible/visual alarms or drive exhaust device).
  • selectable alarm setpoint

0-100%LEL CH4 detector 2 relay and 4-20mA output used in lpg gas and biogas industry for CH4 detection 60-100%LEL CH4 detector 2 relay and 4-20mA output used in lpg gas and biogas industry for CH4 detection 80-100%LEL CH4 detector 2 relay and 4-20mA output used in lpg gas and biogas industry for CH4 detection 10 0-100%LEL CH4 detector 2 relay and 4-20mA output used in lpg gas and biogas industry for CH4 detection 12

Fixed LPG gas leak detector technical specifications

  • Sensor type: original imported electro-chemical sensor for toxic gas, and catalytic combustion sensor for combustible gas.
  •  Resolution:1%LEL, 1%VOL, 1ppm or 0.1ppm
  •  Accuracy:≤ ± 3% F.S
  • Response time:T90<30s.
  • Output signal: 4 to 20mA standard signal(RS485 output optional)
  •  Power supply: 16~30V DC.
  •  Ambient Parameter: Temperature:-20°C~+60°C.  
  • Humidity: < 90%(without condensating)
  • Type of cable: 3 or 4 active wires screened between detector and centralized unit. 3×1.5mm2  for 4-20mA signal OR 4*1.5mm2 for RS485 signal
  • Transmition Distance:<=1000meter
  • Mounting Screw thread: G1/2.
  • Weight:1200g.
  • Anti-explosion Grade: Ex d IICT6Gb
  • Protection Grade:IP66.

 

Detector Model

Gas Detected

Range

Range Optional

Resolution

Responding Time

CO Detector

CO

0-1000ppm

0-500/2000/5000ppm

1ppm

20s

O2 Detector

O2

0-25%VOL

30%VOL

0.1%VOL

20s

O3 Detector

O3

0-10ppm

0-100ppm

0.01ppm

20s

H2S Detector

H2S

0-100ppm

0-50/200/1000ppm

1ppm

30s

H2 Detector

H2

0-1000ppm

0-5000ppm

1ppm

30s

CL2 Detector

CL2

0-20ppm

0-10/100ppm

0.1ppm

30s

NH3 Detector

NH3

0-100ppm

0-50/500/1000ppm

1ppm

30s

SO2 Detector

SO2

0-20ppm

0-50/1000ppm

0.1ppm

30s

NO Detector

NO

0-25ppm

0-500ppm

0.1ppm

30s

NO2 Detector

NO2

0-20ppm

0-50/100ppm

0.1ppm

30s

CH2O Detector

CH2O

0-50ppm

0-5/10ppm

0.01ppm

30s

HCL Detector

HCL

0-20ppm

0-20/100ppm

0.5ppm

30s

Combustible Gas Detector

EX

0-100%LEL

0-100%LEL

1%

30s

For the gas that is not covered here though, please don’t hesitate to contact us.

Fixed LPG gas leak detector product application

0-100%LEL CH4 detector 2 relay and 4-20mA output used in lpg gas and biogas industry for CH4 detection 140-100%LEL CH4 detector 2 relay and 4-20mA output used in lpg gas and biogas industry for CH4 detection 10
  

Company profile

More than 10 years industrial experience

ODM & OEM service

1-3 year warranty

 

3000 square meter factory area

10 production lines

50 experience R&D engineers

0-100%LEL CH4 detector 2 relay and 4-20mA output used in lpg gas and biogas industry for CH4 detection 180-100%LEL CH4 detector 2 relay and 4-20mA output used in lpg gas and biogas industry for CH4 detection 200-100%LEL CH4 detector 2 relay and 4-20mA output used in lpg gas and biogas industry for CH4 detection 10 0-100%LEL CH4 detector 2 relay and 4-20mA output used in lpg gas and biogas industry for CH4 detection 240-100%LEL CH4 detector 2 relay and 4-20mA output used in lpg gas and biogas industry for CH4 detection 260-100%LEL CH4 detector 2 relay and 4-20mA output used in lpg gas and biogas industry for CH4 detection 10 0-100%LEL CH4 detector 2 relay and 4-20mA output used in lpg gas and biogas industry for CH4 detection 300-100%LEL CH4 detector 2 relay and 4-20mA output used in lpg gas and biogas industry for CH4 detection 320-100%LEL CH4 detector 2 relay and 4-20mA output used in lpg gas and biogas industry for CH4 detection 10 0-100%LEL CH4 detector 2 relay and 4-20mA output used in lpg gas and biogas industry for CH4 detection 36

 

 

Related Products

  1. Industrial use: Portable gas detectors, fixed gas detectors, gas leak automation control panel, etc

    Domestic use: household gas detectors, smoke detectors, safety protection instrument, etc.

     0-100%LEL CH4 detector 2 relay and 4-20mA output used in lpg gas and biogas industry for CH4 detection 38

     

Fixed LPG gas leak detector Packing & delivery

 Packaging: Carton box or Aluminum box on your requirement 

Delivery: Sample order in stock and 3-7 working days for bulk production.

Payment: You can pay for the order via T/T, Western Union, PayPal & Money Gram.

Shipping: DHL, TNT, UPS, FEDEX, EMS, CHINA AIR POST.

You can also choose your own shipping forwarder.

0-100%LEL CH4 detector 2 relay and 4-20mA output used in lpg gas and biogas industry for CH4 detection 400-100%LEL CH4 detector 2 relay and 4-20mA output used in lpg gas and biogas industry for CH4 detection 10

FAQ:

1. Can I have a sample order?

A: Yes, we welcome sample order to test and check quality.


2. What is the lead time?

A: Sample needs 1-3 days, mass production time needs 7-15 days for order less than 5000 pcs.

3. Do you have any MOQ limit?

A: We don’t have a MOQ limit, 1 pc are also welcome.

4. Do you offer guarantee for the products?

A: Yes, we offer one or two year guarantee for the products.

5. Do you accept drop shipping?

A: Yes, it’s available.

6. What will your ODM&OEM service cover?

A: a. Customer brand and logo print (law allowed) can be made on the sticker. 

b. Customized color and special function of gas detection tools.

c. Customized box. 

d. Your other ideas about gas detection tools, we can help you design and put them into production.

e. Different language versions, such as English, Russian, Chinese, etc. according to customers requirement.

 

Recommended Products