Portable oxygen gas(O2) detector with internal pumb
Customized Support | OEM, ODM | Enslosure Color | Blue And Yellow |
---|---|---|---|
Alarm Ways | Sound, Dual-color LED Alarm, Vibration | Battery | Inbuilt Rechargeable Lithium Battery |
IP Grade | IP65 | Ex-proof Grade | Ex Ia IIC T4 |
Product Name | Portable Oxygen Gas(O2) Detector With Internal Pumb | Port | China Main Ports |
Portable gas detector GC510 can detect toxic gas, combustible gas, oxygen gas, etc in the working site continuously. It is widely applicable to such application where is explosion-proof, toxic gas leakage emergency rescue, underground or mine, etc, to avoid workers’ life and safety being aggrieved,the equipment being damaged .
GC510 can be equipped with built-in air pump to extract air and test the air sample in the testing area, then transfer the air sample into the gas detector , which is with rapid detection speed. Long distance detection can be performed in the dangerous area to ensure the worker’s safety.
The dispersive gas detection can be operated in the special short distance environment and confined pipes by the external flexible probe( can detect combustible gas only for now)
Features:
♦ Small size, light weight and durable
♦ Adopt embedded 16-bit microprocessor, ensure that the product is in stable and reliable operation.
♦ Visual, audible, vibration alarm.
♦ Chinese or English menu is optional.
♦ Large display screen, easy operation.
♦ Self-test function.
♦ 1000 alarm records storage.
♦ Save and restore the factory setting function.
♦ External flexible probe(Optional) for combustible gas only.
♦ Embedded air pump(Optional).
Specifications
Model
GC510
Gas detection
Single gas(Toxic gas, combustible gas or oxygen)
Sensor
Catalytic combustion type, electric chemical sensors (with temperature compensation), the PID sensor
Response time
T90<30s
Operating temperature
-20℃-50℃
Humidity
5-90%RH no condensation
Display
LCD
Alarm
Flicker, three color LED warning lamp, LCD display, 90dB pulse output, vibration.
Power supply
7.4V rechargeable Li-ion battery
Sampling method
Built-in pump or probe optional
Enclosure
Strong, durable and shockproof.
Calibration
One-click automatic calibration and automatic zero, multi-point calibration can be performed manually.
Data logging
1000
Dimension
227*71*35mm
Weight
220g
Detector Model | Gas Detected | Range | Range Optional | Resolution | Responding Time |
CO Detector | CO | 0-1000ppm | 0-500/2000/5000ppm | 1ppm | ≤20s |
O2 Detector | O2 | 0-25%VOL | 30%VOL | 0.1%VOL | ≤20s |
O3 Detector | O3 | 0-10ppm | 0-100ppm | 0.01ppm | ≤20s |
H2S Detector | H2S | 0-100ppm | 0-50/200/1000ppm | 1ppm | ≤30s |
H2 Detector | H2 | 0-1000ppm | 0-5000ppm | 1ppm | ≤30s |
CL2 Detector | CL2 | 0-20ppm | 0-10/100ppm | 0.1ppm | ≤30s |
NH3 Detector | NH3 | 0-100ppm | 0-50/500/1000ppm | 1ppm | ≤30s |
SO2 Detector | SO2 | 0-20ppm | 0-50/1000ppm | 0.1ppm | ≤30s |
NO Detector | NO | 0-25ppm | 0-500ppm | 0.1ppm | ≤30s |
NO2 Detector | NO2 | 0-20ppm | 0-50/100ppm | 0.1ppm | ≤30s |
CH2O Detector | CH2O | 0-50ppm | 0-5/10ppm | 0.01ppm | ≤30s |
HCL Detector | HCL | 0-20ppm | 0-20/100ppm | 0.5ppm | ≤30s |
Flammable Gas Detector | EX | 0-100%LEL | 0-100%LEL | 1% | ≤30s |
For the gas that is not covered here though, please don’t hesitate to contact us. |